Cement Plant Applied Electric Motor with Squirrel Cage Rotor, IC411, 1000kw, 1120kw, 1250kw, 1350kw

Product Details
Customization: Available
Application: Industrial
Operating Speed: Constant Speed
Manufacturer/Factory, Trading Company
Diamond Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Fast Delivery
The supplier can deliver the goods within 30 days
Low MOQ
The MOQ for the supplier's products is 1
Full Customization
The supplier provides full customization services
to see all verified strength labels (13)
  • Cement Plant Applied Electric Motor with Squirrel Cage Rotor, IC411, 1000kw, 1120kw, 1250kw, 1350kw
  • Cement Plant Applied Electric Motor with Squirrel Cage Rotor, IC411, 1000kw, 1120kw, 1250kw, 1350kw
  • Cement Plant Applied Electric Motor with Squirrel Cage Rotor, IC411, 1000kw, 1120kw, 1250kw, 1350kw
  • Cement Plant Applied Electric Motor with Squirrel Cage Rotor, IC411, 1000kw, 1120kw, 1250kw, 1350kw
  • Cement Plant Applied Electric Motor with Squirrel Cage Rotor, IC411, 1000kw, 1120kw, 1250kw, 1350kw
  • Cement Plant Applied Electric Motor with Squirrel Cage Rotor, IC411, 1000kw, 1120kw, 1250kw, 1350kw
Find Similar Products

Basic Info.

Model NO.
HXR 560LN10
Species
Hxr 560 Series
Rotor Structure
Squirrel-Cage
Casing Protection
Closed Type
Number of Poles
2p-12p
Starting Mode
Direct on-line Starting
Certification
ISO9001, CCC
Rated Power
up to 2250kw
Frequency
50Hz, 60Hz
Voltage
3kv,6kv,10kv
Frame Size
560mm
Cooling Method
IC411/IC416
Mounting Arrangement
Imb3/Imv1
Rotation Direction
Cw/Ccw
Duty Type
S1
Insulation Class
F
Temperature Rise
B
Ambient Temperature
-20 up to 50
Installation Site
Indoor/Outdoor
Protection
IP55/IP66
Space Heater
Yes
Temperature Sensor
Yes
Transport Package
Standard Seaworthy Packing
Origin
China
HS Code
8501530090
Production Capacity
80000

Product Description

1. Product Description 

Rib cooled motors, type HXR  560

HXR rib cooled motors have a rugged cast iron frame. They are totally enclosed fan cooled motors with IC411 cooling and IP55 protection as standard. The motors are also available with IC416 cooling and optional IP66 protection.

HXR motors cover the output range up to 2,250 kW, and they are available in shaft height 560. The motors can be mounted horizontally or vertically.

For HXR motors this catalog shows the technical data at 50 Hz only, but the motors are operating at both 50 Hz and 60 Hz, with synchronous speed from 500 to 3600 rpm.

 

2. Mounting arrangements
Standard mounting arrangements for AXR motors

 
Code I: IM B3
Code II: IM 1001
Standard floor mounting, feet facing downwards (horizontal foot mounted).
Cement Plant Applied Electric Motor with Squirrel Cage Rotor, IC411, 1000kw, 1120kw, 1250kw, 1350kw
Code I: IM V1
Code II: IM 3011
Flange and free shaft end facing downwards
(vertical solid shaft, flange mounted).
Cement Plant Applied Electric Motor with Squirrel Cage Rotor, IC411, 1000kw, 1120kw, 1250kw, 1350kw

 3. Enclosure and cooling
Standard combinations 

IC411 / IP55
HXR motors have an external shaft mounted fan that uses the surrounding air for cooling.
The motors are protected against dust and water jets. The operating principle of these motors is shown in diagram 27 below.

IC416 / IP55
HXR motors are available with IC416 cooling.
An additional motor drives the cooling fan to produce the cooling required for low speed applications, especially in cases where the motor is fed via a variable speed drive.

Protection rating IP55
• Protection against dust: as in other dust- protected motors, some dust can enter but not in sufficient quantities to interfere with the motor's operation.
• Protection against water jets: water projected by a nozzle against the motor from any direction has no harmful effect.

Protection rating IP66
HXR motors are available with protection ratings up to IP66.
• Protection against dust: the enclosure is completely dust tight.
• Protection against water jets: water projected in powerful jets (12.5 mm nozzle) against the enclosure from any direction has no harmful effect.

Cooling method (IC411)
• Frame surface cooled: The primary coolant is circulated in a closed circuit in the motor and gives its heat through the external surface of the motor (in addition to the heat transfer via the stator core and other heat conducting parts) to the final coolant which is the surrounding medium. The surface may be plain or ribbed, with or without an outer shell to improve the heat transfer.
• Self circulation: The coolant is moved dependent on the rotational speed of the main motor either by action of the rotor alone or by means of a component designed for this purpose and mounted directly on the rotor of the main motor, or by a fan or pump unit mechanically driven by the rotor or the main motor.

Cement Plant Applied Electric Motor with Squirrel Cage Rotor, IC411, 1000kw, 1120kw, 1250kw, 1350kw
Cement Plant Applied Electric Motor with Squirrel Cage Rotor, IC411, 1000kw, 1120kw, 1250kw, 1350kwCement Plant Applied Electric Motor with Squirrel Cage Rotor, IC411, 1000kw, 1120kw, 1250kw, 1350kwCement Plant Applied Electric Motor with Squirrel Cage Rotor, IC411, 1000kw, 1120kw, 1250kw, 1350kwCement Plant Applied Electric Motor with Squirrel Cage Rotor, IC411, 1000kw, 1120kw, 1250kw, 1350kw


4. Packaging  

Standard seaworthy package for export
Plywood package or wooden fumigation package
Suitable for long distance transportation by sea/land. 

 

5. Warranty Period

Standard warranty: 12 months after commissioning, or 18 months after delivery, whichever comes first.
If you would like to extend the warranty period, it is allowed, please contact us for more details.



 